<?xml version="1.0" encoding="UTF-8"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-07-20T05:58:17Z</responseDate>
  <request identifier="4529" metadataPrefix="oai_dc" verb="GetRecord">https://drops.dagstuhl.de/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:drops-oai.dagstuhl.de:4529</identifier>
        <datestamp>2024-03-06T10:29:27Z</datestamp>
        <setSpec>ddc:004</setSpec>
        <setSpec>open_access</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Design Pillars for Medical Cyber-Physical System Middleware</dc:title>
          <dc:creator>Arney, David</dc:creator>
          <dc:creator>Plourde, Jeff</dc:creator>
          <dc:creator>Schrenker, Rick</dc:creator>
          <dc:creator>Mattegunta, Pratyusha</dc:creator>
          <dc:creator>Whitehead, Susan F.</dc:creator>
          <dc:creator>Goldman, Julian M.</dc:creator>
          <dc:subject>Medical Device Interoperability</dc:subject>
          <dc:subject>Clinical Requirements</dc:subject>
          <dc:subject>Design Pillars</dc:subject>
          <dc:subject>Requirements Elicitation</dc:subject>
          <dc:subject>Validation</dc:subject>
          <dc:description>Our goal is to improve patient outcomes and safety through medical device interoperability. To achieve this, it is not enough to build a technically perfect system. We present here our work toward the validation of middleware for use in interoperable medical cyber-physical systems. This includes clinical requirements, together with our methodology for collecting them, and a set of eighteen `design pillars' that document the non-functional requirements and design goals that we believe are necessary to build a successful interoperable medical device system. We discuss how the clinical requirements and design pillars are involved in the selection of a middleware for our OpenICE implementation.</dc:description>
          <dc:publisher>Schloss Dagstuhl – Leibniz-Zentrum für Informatik</dc:publisher>
          <dc:contributor>David Arney and Jeff Plourde and Rick Schrenker and Pratyusha Mattegunta and Susan F. Whitehead and Julian M. Goldman</dc:contributor>
          <dc:date>2014</dc:date>
          <dc:relation>Is Part Of OASIcs, Volume 36, 5th Workshop on Medical Cyber-Physical Systems (2014)</dc:relation>
          <dc:type>InProceedings</dc:type>
          <dc:type>Text</dc:type>
          <dc:type>doc-type:ResearchArticle</dc:type>
          <dc:type>publishedVersion</dc:type>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>doi:10.4230/OASIcs.MCPS.2014.124</dc:identifier>
          <dc:identifier>urn:nbn:de:0030-drops-45294</dc:identifier>
          <dc:identifier>https://drops.dagstuhl.de/entities/document/10.4230/OASIcs.MCPS.2014.124</dc:identifier>
          <dc:language>eng</dc:language>
          <dc:rights>https://creativecommons.org/licenses/by/3.0/legalcode</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>